Welcome LABWARE DEALS LAB EQUIPMENT CO., INC
Type Fully Automated Analysis system
Throughput 140 tests per hour
Analytical Methods End point, Kinetic, fixed time, Bi-chromatic, multi-standard, Two steps of end point and more
Assay Modules Over 200 modules
Sample Slots 64 slots for standard and control
Sample Volume 1-100ul, 1ul / step
Reaction tray size 96 reaction cuvettes
Flow cell volume 32 ul
Reagent Diluter : 1000ul, 1ul/step
Reagent Slots
Photometric Measuring range 0.0 – 3.0 OD (filters)
Reagent Volume
Probe Handling With liquid sensor & automatic probe washing and crash function
Washing Reaction Cuvettes Automatic Flow cell washing
Data Transmission USB 2.0
Reaction Time
Alarms Reagent / sample alarm, Water alarm, Hit the needle alarm, Replace the reaction plate
Calibration System Calibration : Deduction of washer blank/ reagent blank
Nonlinear linear or with 1-6 calibration standards
Lamp 7 high-quality 6 V/ 10 W Halogen lamp
Storage Up to millions of analysis reports
Absorbance Resolution
Absorbance Accuracy
Repeatability
Quality Control Levy-Jennings chart and West guard analysis 
Power Supply 220 V / 50 Hz or 110 V / 60 Hz
Dimension 600 x 500 x 410 mm
Weight
Type Fully Automated Random Access System
Throughput Reagent 1 : 400 test/hr
Reagent 2 : 600 test/hr
With ISE : 400 test/hr
Analytical Methods End-point, Multi-standard, Immuno-turbid metric, 1-2 reagent, Reagent/serum blank, etc.
Assay Modules 80 modules
Sample Slots 80
Sample Volume 1µL - 100µL, (0.1µL/step)
Reaction tray size
Flow cell volume
Reagent
Reagent Slots 2 x 40
Photometric Measuring range
Reagent Volume R1 : 1µL - 400µL, (1µL/step)
R2 : 1µL - 400µL, (1µL/step)
1µL - 500µL, (0.1µL/step) [Min. 50 µL/test on request]
Probe Handling Liquid level sensor, Collision sensor, Teflon coating and Automatic washing station.
Washing Reaction Cuvettes 8 channel Auto-washing
Data Transmission
Reaction Time 0 s – 999 s
Alarms Auto-alarm for crucial events (collision, reagent/ sample insufficiency, full waste container, etc.)
Calibration Linear, Non-linear, Multi-point, K factor
Lamp Halogen Lamp
Wavelength : 340 nm – 810 nm
Storage
Absorbance Resolution 0.0001 Abs
Absorbance Accuracy ± 0.0003 Abs ; ( 0 Abs – 2.5 Abs)
Repeatability ≤ 2 %
Quality Control Levy-Jennings quality control at 3 levels
Power Supply 220 V / 50 Hz or 110 V / 60 Hz
Dimension 1000 x 850 x 700 mm
Weight 137 Kgs
Type Fully Automatic Random Access system
Throughput 120 tests/hour
Assay Modules Up to 26 Assays
Sample slots 9
Sample volume 3 µL – 45 µL, (0.5 µL step adjustability)
Reagent slots 26
Reagent volume R1 : 180 µL – 450 µL, (1 µL step adjustability)
R2 : 180 µL – 450 µL, (1 µL step adjustability)
Reaction slots 90 cuvettes, 10 cuvettes/strips
Cuvette (Optical length) 5 mm
Reaction volume 180 µL – 500 µL
Reaction temperature (37° ± 0.4°) C
Probe Handling Pre-heat, Collision protection, Liquid-level detection, Inventory checking, Automatic inner and outer probe washing
Lamp Halogen bulb
Absorbance range (0 Abs – 3.500 Abs) ± 1 %
Wavelength 340 nm – 700 nm
Resolution 0.0001 Abs
Temperature 10°C - 35°C
Humidity 35% – 80%
Reagent refrigeration 4°C - 15°C
Water Consumption 1.5 L/hr
Power Supply 100 V – 240 V ; 50/60 Hz
Dimension 583 x 453 x 530 cm
Weight 70 Kgs