Type | Fully Automated Analysis system |
Throughput | 140 tests per hour |
Analytical Methods | End point, Kinetic, fixed time, Bi-chromatic, multi-standard, Two steps of end point and more |
Assay Modules | Over 200 modules |
Sample Slots | 64 slots for standard and control |
Sample Volume | 1-100ul, 1ul / step |
Reaction tray size | 96 reaction cuvettes |
Flow cell volume | 32 ul |
Reagent | Diluter : 1000ul, 1ul/step |
Reagent Slots | |
Photometric Measuring range | 0.0 – 3.0 OD (filters) |
Reagent Volume | |
Probe Handling | With liquid sensor & automatic probe washing and crash function |
Washing Reaction Cuvettes | Automatic Flow cell washing |
Data Transmission | USB 2.0 |
Reaction Time | |
Alarms | Reagent / sample alarm, Water alarm, Hit the needle alarm, Replace the reaction plate |
Calibration | System Calibration : Deduction of washer blank/ reagent blank Nonlinear linear or with 1-6 calibration standards |
Lamp | 7 high-quality 6 V/ 10 W Halogen lamp |
Storage | Up to millions of analysis reports |
Absorbance Resolution | |
Absorbance Accuracy | |
Repeatability | |
Quality Control | Levy-Jennings chart and West guard analysis |
Power Supply | 220 V / 50 Hz or 110 V / 60 Hz |
Dimension | 600 x 500 x 410 mm |
Weight |
Type | Fully Automated Random Access System |
Throughput | Reagent 1 : 400 test/hr Reagent 2 : 600 test/hr With ISE : 400 test/hr |
Analytical Methods | End-point, Multi-standard, Immuno-turbid metric, 1-2 reagent, Reagent/serum blank, etc. |
Assay Modules | 80 modules |
Sample Slots | 80 |
Sample Volume | 1µL - 100µL, (0.1µL/step) |
Reaction tray size | |
Flow cell volume | |
Reagent | |
Reagent Slots | 2 x 40 |
Photometric Measuring range | |
Reagent Volume | R1 : 1µL - 400µL, (1µL/step) R2 : 1µL - 400µL, (1µL/step) 1µL - 500µL, (0.1µL/step) [Min. 50 µL/test on request] |
Probe Handling | Liquid level sensor, Collision sensor, Teflon coating and Automatic washing station. |
Washing Reaction Cuvettes | 8 channel Auto-washing |
Data Transmission | |
Reaction Time | 0 s – 999 s |
Alarms | Auto-alarm for crucial events (collision, reagent/ sample insufficiency, full waste container, etc.) |
Calibration | Linear, Non-linear, Multi-point, K factor |
Lamp | Halogen Lamp Wavelength : 340 nm – 810 nm |
Storage | |
Absorbance Resolution | 0.0001 Abs |
Absorbance Accuracy | ± 0.0003 Abs ; ( 0 Abs – 2.5 Abs) |
Repeatability | ≤ 2 % |
Quality Control | Levy-Jennings quality control at 3 levels |
Power Supply | 220 V / 50 Hz or 110 V / 60 Hz |
Dimension | 1000 x 850 x 700 mm |
Weight | 137 Kgs |
Type | Fully Automatic Random Access system |
Throughput | 120 tests/hour |
Assay Modules | Up to 26 Assays |
Sample slots | 9 |
Sample volume | 3 µL – 45 µL, (0.5 µL step adjustability) |
Reagent slots | 26 |
Reagent volume | R1 : 180 µL – 450 µL, (1 µL step adjustability) R2 : 180 µL – 450 µL, (1 µL step adjustability) |
Reaction slots | 90 cuvettes, 10 cuvettes/strips |
Cuvette (Optical length) | 5 mm |
Reaction volume | 180 µL – 500 µL |
Reaction temperature | (37° ± 0.4°) C |
Probe Handling | Pre-heat, Collision protection, Liquid-level detection, Inventory checking, Automatic inner and outer probe washing |
Lamp | Halogen bulb |
Absorbance range | (0 Abs – 3.500 Abs) ± 1 % |
Wavelength | 340 nm – 700 nm |
Resolution | 0.0001 Abs |
Temperature | 10°C - 35°C |
Humidity | 35% – 80% |
Reagent refrigeration | 4°C - 15°C |
Water Consumption | 1.5 L/hr |
Power Supply | 100 V – 240 V ; 50/60 Hz |
Dimension | 583 x 453 x 530 cm |
Weight | 70 Kgs |