Welcome LABWARE DEALS LAB EQUIPMENT CO., INC
Tidal Volume 20 ml ~ 500 ml
Standard Ventilation Mode VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH
Application Adult/ Pediatric Invasive
Pressure Range 5 mbar ~ 80 mbar
Respiration rate range 1 bpm ~ 99 bpm
1 bpm ~ 40 bpm under SIMV
I:E Ratio 4:1 to 1:8
Oxygen Concentration 21 % ~ 100 %
Pressure trigger Range -20 to 20 cmH2O
PEEP Type Integrated, Electronic Control
PEEP Range 0 to 30 cmH2O
Gas Supply O2, Air ( 280 kPa ~ 600 kPa )
Alarm Visual : No tidal volume, MV, Paw, FiO2 limitation O2, Air failure, AC power failure, low back up
Audio: No tidal volume, MV, Paw, FiO2 limitation
Display 12.1” Color LCD
Graphic Display Waveforms of P-T, F-T, V-T
Operating Temperature 5 °C ~ 40 °C
Storage Temperature -10 °C to 40 °C
Relative Humidity ≤ 80 %
Atmospheric Pressure 96 kPa ~ 104 kPa
Battery Lead acid 12V, 4Ah (120 mins run time)
Output Pressure 0.4 mPa ± 0.1 mPa
Noise ≤ 50 dB
Power Supply AC 220 V ± 10 %, 50 Hz ± 2 %
Dimension 450 x 550 x 1400 mm
Weight 65 kgs
Tidal Volume 10 ml ~ 300 ml
Standard Ventilation Mode CMV, IMV, CPAP, Manual
Application Pediatric
Inspiratory Flow 3 L/min ~ 20 L/min
Respiration rate 1 bpm ~120 bpm
I:E Ratio 1:1 to 1:3
Oxygen Concentration 21 % ~ 100 %
Pressure trigger Range -1.0 to 0 kPa
Flow Trigger Range 0 to 10 L
PEEP Type Pneumatic Driven, Electronic Control
Inspiratory Pause Time 0.2 s ~ 3.0 s
Maximum Security Pressure ≤ 10 kPa
PEEP Range 0 kPa ~2.0 kPa
Max Ventilation Volume > 5 L/min
Input Pressure 0.15 MPa ~ 0.3 Mpa
Inspiratory Pressure 1 kPa ~ 9 kPa
Dimension
Weight
Tidal Volume 20 ml ─ 2500 ml
Configurations Trolley or Ceiling Pendant
Respiratory Rate 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV)
4 bpm ─ 100 bpm ( VCV/PCV/PRVC)
Psupport 0 kPa ─ 6 kPa
Pcontrol 0.5 kPa ─ 6 kPa
Pulmonary Mechanics Waveform 3
Loops 2
Standard Ventilation Modes VCV (A/C)
PCV (A/C)
SIMV (VCV)
SIMV(PCV)
SIMV (PRVC)
SPONT/CPAP
NIV/CPAP
NIV/PCV
BIVENT
Combined Ventilation Modes SPONT+PS
SIMV(VCV)+ PS
SIMV(PCV)+PS
SIMS(PRVC)+PS
BIVENT+PS
VCV+SIGH
NIV/CPAP+PS
Inspiration Time 0.1 s ─ 12 s
Inspiratory Pause Time 0 s ─ 4 s
FiO2 Range 21% ─ 100%
Trigger Sensitivity Pressure : - 2 kPa to 0 kPa (above PEEP)
Flow : 0.5 LPM ─ 20 LPM (base flow)
PEEP 0 kPa ─ 5 kPa
Suction < 2 min
Nebulizer 30 mins
Pressure Values Pplat / Ppeak / Pmean / PEEP
Volume / Flow values VTI / VTE / MV / MVspont
Time Values Ftotal / Fspont / I : E
Oxygen Monitoring Without O2 sensor ( O2 sensor optional )
Gas Supply O2, Air (0.28 MPa – 6 MPa)
Real-time Curves Pressure-Time
Flow-Time
Volume-Time
Pressure-Volume loop
Flow-Volume loop
Alarm Upper and Lower limits : MV, Paw, PEEP, Airway Pressure continuous high, VTE, Fspont high
Other Conditions : Tapnea, ,Power Fail, Nebulizer, Battery low, Battery exhausted, Air supply failure, O2 supply failure, Air and O2 supply failure, Fan block, Pipe block, Circuit disconnected
Display 12.1” TFT LCD touch screen
Internal Battery > 1 hour
Maximum Security Pressure ≤ 8 kPa
Compliance ≤ 4 ml / 100 Pa
Noise ≤ 65 dB (A)
Communication RS232, VGA, Nurse Call
Operational Temperature 5 °C to 40 °C
Relative Humidity ≤ 90 % (non-condensing)
Atmospheric Pressure 50 kPa – 106 kPa
Power Supply 110 V – 240 V (50 Hz / 60 Hz), 65 VA
Dimensions 328 x 410 x 410 mm
Weight 20 Kgs
Tidal Volume 0 ml – 1500 ml
Gas Supply O2, 0.28 to 0.6 MPa
Ventilation Modes A/C, SIMV, SPONT, Manual, VCV+SIGH
Respiratory Rate 4 bpm – 40 bpm (SIMV)
4 bpm – 99 bpm (A/C)
Range Of I:E Ratio 2:1 to 1: 4
FiO2 Range 48% to 100%
Pressure Sensitivity Above PEEP: - 2 kPa to 0 kPa
PEEP: 0.5 kPa to 2 kPa
Pressure Parameter Ppeak
Volume/Flow Parameter Vt , MV
Time Parameter Ftotal
Real-Time Curves Pressure-Time
Compliance < 4 ml/100 Pa
Cylinder Capacity 3.2 L
Max. Pressure < 6 kPa
Battery Life 4 Hours of Uninterrupted Battery life
Environmental Temperature Operation: -10°C to 50°C
Storage: -20°C to 55°C
Relative Humidity Operation: < 85 %
Storage: < 93 %
Atmospheric Pressure Operation: 70 kPa – 110 kPa
Storage: 50 kPa – 110 kPa
Power Supply 110 V - 220 V, 50/60Hz , < 65 VA
Dimensions 175 x 170 x 300 mm
Weight 3.5 Kgs