Patient range | Adult, pediatric, neonate |
NIBP Measurement method | Oscillometric |
NIBP Measurement range | 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg) |
NIBP Measurement mode | Arm Measurement |
NIBP Measurement interval | 15, 30, 60, 120, 240 min (Auto mode ) |
NIBP - Resolution | 1 mmHg |
NIBP - Accuracy | ± 3 mmHg |
Pulse Rate Measurement range | 40 bpm – 240 bpm |
Pulse rate - Resolution | 1 bpm |
Pulse rate - Display | 2.4” color TFT – LCD |
Power Supply | DC : 3 V |
Alarm | SYS, DIA (User defined) |
Storage | Auto mode : up to 350 results Manual mode : up to 300 results |
Dimension | 128 × 69 × 36 mm |
Weight | < 300 g |
Temperature Range | 37°C to 42°C |
Temperature Accuracy | ± 0.5°C |
Warm-up Time | < 45 s (20°C to 36°C) |
Power Consumption | 250 VA |
Warming Capacity | Up to 6000 ml/hr |
Tube Diameter Range | |
Device Classification | Class I, Type B |
Overheat Protection | 43 °C / 45 °C / (48 ± 3 ) °C |
Low Temperature Alarm | 36 °C |
Power Supply | |
Dimensions | 100 x 170 x 210 mm |
Weight | 1.3 Kg |
Temperature Range | 37°C to 42°C |
Temperature Accuracy | ± 1.0°C |
Warm-up Time | < 45 s (20°C to 36°C) |
Power Consumption | 80 VA |
Warming Capacity | 16 ml/min |
Tube Diameter Range | 3.5 mm ̶ 5.0 mm O.D. |
Device Classification | Class I, Type B |
Overheat Protection | 43°C / 45°C / (48 ± 3)°C |
Low Temperature Alarm | 36 °C |
Power Supply | 230 V ± 10%, 50 ̶ 60 Hz |
Dimensions | 180 x 75 x 40 mm |
Weight |
Display | 12.1” LCD display |
Ultrasound frequency | 1024 (1 ± 10%) kHz |
Max output intensity | < 10 MW/cm2 |
FHR measurement range | 30 bpm ~ 240 bpm |
FHR sensitivity | ≤ 2 bpm |
FHR alarm range | 30 bpm ~ 240 bpm |
Alarm time | ≤ 30s |
Alarm limits | FHR Higher [User defined] FHR Lower [User defined] TOCO Higher [User defined] TOCO Lower [User defined] |
TOCO measurement range | 0 ~ 100 units |
TOCO baseline | 0 ~ 20 units |
TOCO sensitivity | ≤ 10 % |
Recorder paper speed | 1,2,3 cm/min |
Recorder deviation | ≤ 5 % |
Print duration | 5 min – 240 min |
Safety standard | Class I, BF type |
Storage temperature range | 40℃ ~ 55℃ |
Storage relative humidity | ≤ 93 % |
Storage pressure range | 500 hPa ~ 1060hPa |
Operational temperature range | 10°C ~ 40°C |
Relative humidity | ≤ 80 % |
Atmosphere pressure | 70 kPa ~ 106 kPa |
Weight | 4.5 Kgs |
Display | 7-inch screen |
Waveform | Biphasic |
Manual with Sync mode | 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules |
AED mode | Auto analyze and charge x 3 with programmable auto energy level selection. |
Interpreted rhythms for AED | Ventricular fibrillation ≥ 200 µV Ventricular tachycardia ≥ 140 bpm QRS complex wave duration ≥ 140 ms |
Sweep Speed | 25 mm/s |
Electrode impedance range | 0 Ω – 250 Ω |
Analysis Time | Less than 7 seconds |
ECG Lead selection | Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V |
ECG Heart rate | 20 bpm – 300 bpm |
ECG size | 0.25, 0.5, 1, 1.5, 2, 4 cm/mV |
ECG Heart Rate alarm | On / Off displayed on monitor, user-selectable |
SpO2measurement | 30 % – 100 % |
Recorder Paper Speed | 12.5 mm/s, 25 mm/s, 50 mm/s |
Alarm accuracy | ±10 % (less than 12 sec) |
Print modes | Manual or automatic, user-configurable |
Battery | Rechargeable, Ni-MH battery, 12V |
Dimensions | 500 x 380 x 360 mm |
Weight | 8 Kgs |
Waveform | Biphasic |
Energy Sequence | 150 J, 200 J |
Analysis Time | 9 seconds |
Audio Indications | 20 distinct voice instructions |
Charge Time | 8 seconds for 150 J 10 seconds for 200 J |
Capacity | 100 discharges (200 J) 120 discharges (150 J) |
Rhythm Analysis Time | Less than 30 secs for new battery Less than 35 secs after 6 shock discharge Less than 25 secs at initial switch-on |
Visual Indications | LED flash light indicator |
Control Keys | Shock and On/Off keys |
Energy Accuracy | ± 15 % tolerance (25 Ω to 175 Ω) |
Impedance Range | 20 Ω to 200 Ω |
Battery | Non-rechargeable (12V DC) |
Operating Temperature | 0 °C to 40 °C |
Operating Humidity | 30 % to 95 % |
Dimensions | 303 x 216 x 89 mm |
Weight | 2 Kgs |
Display | OLED 160 x 128 dot matrix display |
Storage | Built-in TF card storage for up to 2 GB |
Standard Sensitivity | 10 mm/mV ± 5% |
Sensitivity Shift | ≤ ± 10% |
Channel Display | 12 Channel |
Scan Speed | 25 mm/s ± 5% |
Pacing Analysis | Dual chamber pacing, Atrial pacing, Ventricular pacing module Ventricular Pseudofusion and Ventricular asynchronous module |
Arrhythmia Analysis | MCSSTM and TMCATM |
ECG-Analysis | ST segment analysis , HRT analysis, T-Wave alternation,QTD (QT dispersion) VCG (vector cardiogram), VLP (ventricular late potential) and TVCG (time vector cardiogram) analysis |
Heart-rate Analysis | Short range : 5 minutes Long range : 1 hour Continuous : 24 hours |
Sampling | Sampling Accuracy : 12 Bit Rate of Sampling : 10 kHz |
Batteries | 2 AA batteries |
Interface | USB 2.0 |
Scale Voltage | 1mV ± 5% |
Noise | ≤ 30µV |
CMRR | ≥ 60 dB |
Time Constant | ≥ 3.2 s |
Polarization voltage | ± 300 mV (DC) |
Dimension | 111 x 60 x 25 mm |
Weight | 105 g |
Control System | Air-temp control, Skin-temp control & Humidity control |
Display | LED display |
Air Temperature Control range | 25°C ~ 37°C (Override : 37°C ~ 39°C) |
Baby Temperature Control range | 25°C ~ 37°C (Override : 37°C ~ 39°C) |
Humidity Control range | 40 % ~ 80 % RH |
Humidity Monitoring | 20 % ~ 90 % RH |
Temperature Variability | ≤ 0.5°C |
Temperature Uniformity (On Mattress) | ≤ 0.8°C |
Access ports | 2 ports, 4 windows |
Temperature Resolution | 0.1°C |
Temperature Accuracy | ± 0.3°C |
Humidity Accuracy | ± 5 % RH |
Hybrid Control | Ultrasonic and Steam humidifier |
Water Tank Capacity | 1000 ml |
Alarms | Audio-visual indicators. Air-temperature deviation, Over Air temp, Sensor fail, Humidity deviation, Water shortage in tank |
Mattress Size | 630 × 340 mm |
Bassinet Tilt | ± 12° continuous tilt |
Power Supply | 110 V ~ 120 V, 50/60 Hz 220 V ~ 240 V, 50/60 Hz |
Data Transfer | RS-232 |
Dimensions | 1160 x 720 x 1650 mm |
Weight | 95 Kgs |
Control System | Air-temp control & Skin-temp control |
Display | LED display |
Air Temperature Control range | 25°C ~ 37°C (Override : 37°C ~ 39°C) |
Baby Temperature Control range | 25°C ~ 37°C (Override : 37°C ~ 39°C) |
Humidity Control range | |
Humidity Monitoring | |
Temperature Variability | ≤ 0.5°C |
Temperature Uniformity (On Mattress) | ≤ 0.8°C |
Access ports | 2 ports, 4 windows |
Temperature Resolution | 0.1°C |
Temperature Accuracy | ± 0.3°C |
Humidity Accuracy | ± 5 % RH |
Hybrid Control | |
Water Tank Capacity | 1000ml |
Alarms | Audio-visual indicators. Air-temperature deviation, Over Air temp, Sensor fail, Water shortage in tank |
Mattress Size | 630 × 340 mm |
Bassinet Tilt | ± 12° continuous tilt |
Power Supply | 110 V ~ 120 V, 50/60 Hz 220 V ~ 240 V, 50/60 Hz |
Data Transfer | RS-232 |
Dimensions | 1160 x 720 x 1650 mm |
Weight | 90 Kgs |
Control System | Air-temp control |
Display | LED display |
Air Temperature Control range | 25°C ~ 37°C |
Baby Temperature Control range | |
Humidity Control range | |
Humidity Monitoring | |
Temperature Variability | ≤ 0.5°C |
Temperature Uniformity (On Mattress) | ≤ 0.8°C |
Access ports | 2 ports, 4 windows |
Temperature Resolution | 0.1°C |
Temperature Accuracy | ± 0.3°C |
Humidity Accuracy | ± 5% RH |
Hybrid Control | |
Water Tank Capacity | 1000ml |
Alarms | Audio-visual indicators. Air-temperature deviation, Over Air temp, Sensor fail, Water shortage in tank |
Mattress Size | 630 × 340 mm |
Bassinet Tilt | ± 12° continuous tilt |
Power Supply | 110 V ~ 120 V, 50/60 Hz 220 V ~ 240 V, 50/60 Hz |
Data Transfer | RS-232 |
Dimensions | 1160 x 720 x 1650 mm |
Weight | 75 Kgs |
Channel | Single channel infusion |
Volume (VTBI) | 1 ml ~ 9999.9 ml ( 0.1 ml increment) |
Accuracy | Flow rate: ≤ ± 3 % Mechanical: ≤ ± 2 % |
KVO Rate | 1 ml/h (1 ml/h ~ 300 ml/h) 3 ml/h (greater than 300 ml/h) |
Occlusion System | 3 selectable occlusion levels |
Drop Rate | 1 drop/min ~ 400 drops/min (1 drop/min increment) |
Infusion Rate | 1.0 ml/h ~99.9 ml/h (0.1 ml/h increment) 100 ml/h ~1200 ml/h (1 ml/h increment) |
Purge | 800 ml/h |
Bolus | 10 ml/h ~ 1200 ml/h at 0.1 ml/h (flow rate < 100 ml/h) 10 ml/h ~ 1200 ml/h at 1 ml/h (flow rate > 100 ml/h) |
Therapy Timer Range | 1 min ~ 9999 min ( 1 min increment) |
Display | 4.3-inch colour LCD with backlight |
Drug Library | Database of up to 210 drugs |
Memory | Up to 1500 record entries |
Occlusion Threshold | High: 800 mmHg ± 200 mmHg (106.7 kPa ± 26.7 kPa) Medium: 500 mmHg ± 100 mmHg (66.7 kPa ± 13.3 kPa) Low: 300 mmHg ± 100 mmHg (40.7 kPa ± 13.3 kPa) |
Sensitivity [Bubble detection] | > 25 μL |
Environmental Condition : Operation | Operating temperature 5 ⁰C ~ 40 ⁰C Operating humidity 20 % ~ 90 % |
Environmental Condition: Storage | Storage temperature -10 ⁰C ~ 55 ⁰C Storage humidity 10 % ~ 90 % |
Fuse | F1AL / 250 V |
Power Supply | AC 85 ~ 265 V, 50/60 Hz, < 40 VA |
Battery | 11.1 V rechargeable Li-ion battery; > 2000 mAh Works more than 4 hours at 25 ml/h after charging for 8 hours |
Dimensions | 188 x 198 x 228 mm |
Weight | 2.5 Kgs |
Channel | Single channel infusion |
Infusion Volume | 0 ml ~ 9999 ml ( 0.1ml increment) |
Infusion Rate | 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment) |
KVO Rate | 0.01 ml/h – 5 ml/h |
Occlusion | 4 selectable levels of occlusion |
Accuracy | ±5% |
Infusion Modes | Rate mode, Time mode, Body weight, Drip mode, Micro mode |
Drop Rate | 1 drop/min ~ 400 drops/min (1 drop/min increment) |
Purge | Available |
Bolus | 0.1 ml/h ~1200 ml/h (auto & manual bolus control) |
Therapy Timer Range | 1 min ~ 9999 min ( 1 min increment) |
Display | 4.3-inch colour LCD with backlight |
Drug Library | Database of up to 30 drugs |
Memory | Up to 5000 record entries |
Safety | Class I, CF |
Moisture Protection | IP24 |
Stand by | 00 mins – 99 h 59 mins |
Free-flow Protection | Anti-free flow safeguard clip lock system |
Power Supply | AC: 110 V ~ 240 V, 50 Hz / 60 Hz, DC: 12 V |
Battery | 11.1 V rechargeable Li-ion battery; > 2600 mAh Works more than 9 hours at 25 ml/h after charging for 5 hours |
Dimensions | 235 x 95 x 120 mm |
Weight | 1.6 Kg |
Tidal Volume | 20 ml ~ 500 ml |
Standard Ventilation Mode | VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH |
Application | Adult/ Pediatric Invasive |
Pressure Range | 5 mbar ~ 80 mbar |
Respiration rate range | 1 bpm ~ 99 bpm 1 bpm ~ 40 bpm under SIMV |
I:E Ratio | 4:1 to 1:8 |
Oxygen Concentration | 21 % ~ 100 % |
Pressure trigger Range | -20 to 20 cmH2O |
PEEP Type | Integrated, Electronic Control |
PEEP Range | 0 to 30 cmH2O |
Gas Supply | O2, Air ( 280 kPa ~ 600 kPa ) |
Alarm | Visual : No tidal volume, MV, Paw, FiO2 limitation O2, Air failure, AC power failure, low back up Audio: No tidal volume, MV, Paw, FiO2 limitation |
Display | 12.1” Color LCD |
Graphic Display | Waveforms of P-T, F-T, V-T |
Operating Temperature | 5 °C ~ 40 °C |
Storage Temperature | -10 °C to 40 °C |
Relative Humidity | ≤ 80 % |
Atmospheric Pressure | 96 kPa ~ 104 kPa |
Battery | Lead acid 12V, 4Ah (120 mins run time) |
Output Pressure | 0.4 mPa ± 0.1 mPa |
Noise | ≤ 50 dB |
Power Supply | AC 220 V ± 10 %, 50 Hz ± 2 % |
Dimension | 450 x 550 x 1400 mm |
Weight | 65 kgs |
Tidal Volume | 10 ml ~ 300 ml |
Standard Ventilation Mode | CMV, IMV, CPAP, Manual |
Application | Pediatric |
Inspiratory Flow | 3 L/min ~ 20 L/min |
Respiration rate | 1 bpm ~120 bpm |
I:E Ratio | 1:1 to 1:3 |
Oxygen Concentration | 21 % ~ 100 % |
Pressure trigger Range | -1.0 to 0 kPa |
Flow Trigger Range | 0 to 10 L |
PEEP Type | Pneumatic Driven, Electronic Control |
Inspiratory Pause Time | 0.2 s ~ 3.0 s |
Maximum Security Pressure | ≤ 10 kPa |
PEEP Range | 0 kPa ~2.0 kPa |
Max Ventilation Volume | > 5 L/min |
Input Pressure | 0.15 MPa ~ 0.3 Mpa |
Inspiratory Pressure | 1 kPa ~ 9 kPa |
Dimension | |
Weight |
Tidal Volume | 20 ml ─ 2500 ml |
Configurations | Trolley or Ceiling Pendant |
Respiratory Rate | 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV) 4 bpm ─ 100 bpm ( VCV/PCV/PRVC) |
Psupport | 0 kPa ─ 6 kPa |
Pcontrol | 0.5 kPa ─ 6 kPa |
Pulmonary Mechanics Waveform | 3 |
Loops | 2 |
Standard Ventilation Modes | VCV (A/C) PCV (A/C) SIMV (VCV) SIMV(PCV) SIMV (PRVC) SPONT/CPAP NIV/CPAP NIV/PCV BIVENT |
Combined Ventilation Modes | SPONT+PS SIMV(VCV)+ PS SIMV(PCV)+PS SIMS(PRVC)+PS BIVENT+PS VCV+SIGH NIV/CPAP+PS |
Inspiration Time | 0.1 s ─ 12 s |
Inspiratory Pause Time | 0 s ─ 4 s |
FiO2 Range | 21% ─ 100% |
Trigger Sensitivity | Pressure : - 2 kPa to 0 kPa (above PEEP) Flow : 0.5 LPM ─ 20 LPM (base flow) |
PEEP | 0 kPa ─ 5 kPa |
Suction | < 2 min |
Nebulizer | 30 mins |
Pressure Values | Pplat / Ppeak / Pmean / PEEP |
Volume / Flow values | VTI / VTE / MV / MVspont |
Time Values | Ftotal / Fspont / I : E |
Oxygen Monitoring | Without O2 sensor ( O2 sensor optional ) |
Gas Supply | O2, Air (0.28 MPa – 6 MPa) |
Real-time Curves | Pressure-Time Flow-Time Volume-Time Pressure-Volume loop Flow-Volume loop |
Alarm | Upper and Lower limits : MV, Paw, PEEP, Airway Pressure continuous high, VTE, Fspont high Other Conditions : Tapnea, ,Power Fail, Nebulizer, Battery low, Battery exhausted, Air supply failure, O2 supply failure, Air and O2 supply failure, Fan block, Pipe block, Circuit disconnected |
Display | 12.1” TFT LCD touch screen |
Internal Battery | > 1 hour |
Maximum Security Pressure | ≤ 8 kPa |
Compliance | ≤ 4 ml / 100 Pa |
Noise | ≤ 65 dB (A) |
Communication | RS232, VGA, Nurse Call |
Operational Temperature | 5 °C to 40 °C |
Relative Humidity | ≤ 90 % (non-condensing) |
Atmospheric Pressure | 50 kPa – 106 kPa |
Power Supply | 110 V – 240 V (50 Hz / 60 Hz), 65 VA |
Dimensions | 328 x 410 x 410 mm |
Weight | 20 Kgs |
Control System | Microprocessor based temperature control system |
Control Modes | Preheat, Manual and Skin-temp mode |
Manual : Heater output | 0-100%, 10% increments |
Skin-temp : Control range | 25 °C ~ 37 °C |
Heater Source | Far-infrared heater (Silicon Carbide) |
Skin-temp : Display range | 25 °C ~ 42 °C |
Temperature Resolution | 0.1 |
Display | Digital LED display |
APGAR Timer | 1min / 5min / 10min |
Alarm | High/Low Temperature, Sensor failure, Power failure, Heater failure, System failure |
Heater Head | Adjustable ± 90° |
Infant Bassinet | ±15°continuous tilt with under bed X-ray cassette tray |
Bassinet Panel | Acrylic |
Lateral Shelf | Fixed shelf Load carrying capacity : 2 Kgs |
Mattress Size | 570 × 760 mm |
Temperature Sensor | NTC thermistor 2.25K |
Power Consumption | ≤ 800 VA |
Power Supply | 110 V ~ 120 V, 50/60 Hz 220 V ~ 240 V, 50/60 Hz |
Dimensions | 935 x 650 x 1833 mm |
Weight | 75 Kgs |
Vital Parameters |
|
||||||
Display | 240 x 320 dot matrix colour TFT | ||||||
NIBP Measurement range | Adult: 30-255 mmHg Paediatric: 30-160 mmHg | ||||||
NIBP Mode | Auto, Manual, STAT | ||||||
NIBP Parameters | SYS, DIA, MAP | ||||||
NIBP interval | Auto mode: 1, 2 , 3, 5, 10, 15, 20, 25, 30, 45, 60 mins STAT mode: 5 mins | ||||||
Resolution | 1 mmHg | ||||||
NIBP Over-pressure protection | Adult: 300 mmHg Pediatric: 22 mmHg | ||||||
SpO2 Measurement range | 0 - 100% | ||||||
SpO2 Accuracy | ±2% (90-100)%, ±3% (70-89)%, <70% (unspecified) | ||||||
SpO2 Resolution | 0.01 | ||||||
PR Measurement range | 30 bpm - 250 bpm | ||||||
PR Accuracy | ±1 bpm | ||||||
PR Resolution | 1bpm | ||||||
Temp Probe | Body sensitive temperature sensor | ||||||
Temp Measurement range | 0⁰C to 50⁰C | ||||||
Temp Accuracy | ± 0.1⁰C | ||||||
Temp Resolution | 0.1⁰C | ||||||
Graphic LCD size | 44 x 59 mm | ||||||
Audio-visual Alarms | Sensor-off alarm, Measurement out of user-defined limits | ||||||
Data Transmission | USB-based transmission to PC Internet-based tele monitoring | ||||||
Operational Temperature | 0⁰C to 45⁰C | ||||||
Relative Humidity | 15% to 95% | ||||||
Pressure | 86 kPa – 106 kPa | ||||||
Power Supply | Input power: AC 100-240V, 50-60Hz, 0.7A Output power: 5V,2.5A | ||||||
Battery | 2.8 A built-in rechargeable Li-ion battery Run Time : 5 hours Charging Time : 8 hours |
Vital Parameters | 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP) |
NIBP Measurement range | Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg |
NIBP Mode | Manual, Auto |
NIBP Parameters | Sys, Dia, MAP |
NIBP interval | Auto Mode: 1 ~ 240 min, < 10 s |
NIBP Over-pressure protection | Adult: 300 mmHg Child: 140 mmHg |
SpO2 Measurement range | 35 % ~ 100 % |
SpO2 Accuracy | 75 % ~ 100 % @ ± 2 % 35 % ~ 74 % @ ± 3 % |
PR Measurement range | 30 bpm ~ 250 bpm |
PR Accuracy | ±2 bpm |
TEMP Monitoring range | 21 ⁰C ~ 50 ⁰C |
TEMP Monitoring accuracy | ±0.1 ⁰C |
TEMP Responding time | ≤ 150 s |
Recording speed | 25 mm/s |
Recording speed accuracy | ≤ 5% |
Power Supply | AC 100-250V, 50-60Hz |
Battery | 12 V, 2.3 AH (Lead-acid battery) |
Standard Parameter | 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR |
Patient Groups | Neonate, Pediatric, Adults |
Trace | 9 waveform (ECG,SpO2, RESP) |
ECG Lead Mode | 5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL |
ECG Waveform | 3 and 7 channel selectable |
ECG Gain selection | 0.5mm/mv 1mm/mv 2mm/mv |
ECG Sweep Speed | 12.5 mm/s 25 mm/s 50 mm/s |
Heart Rate range | Adult : 15 ~ 300 bpm Neonate /Pediatric : 15 bpm ~ 350 bpm Alarm range : 15 ~ 350 bpm |
ECG Accuracy | +1 bpm |
ECG Resolution | 1 bpm |
Protection | withstands 4000VAC/50 voltage isolation |
S‐T segment analysis | Range : -2.0 mV ~ +2.0 mV Accuracy: ‐0.8mV ~ +0.8mv Error: +0.02Mv |
Arrhythmia analysis | |
Scaling | 1mv, +3% |
SpO2 Measurement range | 0% ~ 100% Alarm range : 0% ~ 100% |
SpO2 Accuracy | ±2 % (70 % – 100 %) 0 – 69% unspecified |
SpO2 Pulse Rate | Range : 20bpm ~ 300bpm Resolution: 1bpm Error: +1bpm |
NIBP Method | Digital Automatic Oscillometric |
NIBP Operation Mode | Manual/Automatic/Continuous for Systolic, Diastolic and Mean |
Auto Measurement | Adjustable Duration : 1 ~ 480 mins |
Range Of Systolic Pressure | Adult: 40 ~ 270mmHg Pediatric: 40 ~ 220mmHg Neonate: 40 ~ 135 mmHg |
Range Of Diastolic Pressure | Adult: 10 ~ 215 mmHg Pediatric: 10 ~ 150 mmHg Neonate :10 ~ 100 mmHg |
Over‐pressure Protection | Double safety protection |
Respiratory Method | Thoracic impedance |
Respiratory Measurement range | Adult: 7 ~ 120 rpm Neonate/Pediatric: 7 ~ 150 rpm |
Apnea Alarm | 10s ~ 40s |
Respiratory Resolution | 1 rpm |
Respiratory Accuracy | ±2 bpm |
Temp Measurement range | 5 ℃ ~ 50 ℃ |
Average Measuring Time | < 10 sec |
Temp Resolution | 0.1℃ |
Temp Accuracy | ± 0.1℃ |
Display | 12.1’’color TFT |
Resolution | 800 x 600 dot pixels |
Trend | 5 s/piece, 8 hours 5min/piece, 1000 hours |
Alarm | User‐adjustable 3‐level Audio-visual alarm. |
Safety Standard | Class I, type CF |
Working Temperature | 0 ~ 40℃ |
Relative Humidity | ≤ 85 % |
Power Supply | AC 100 ‐ 240 V, 50/60 Hz |
Battery | Rechargeable Lead acid cell, 12 V/4 Ah |
Storage | NIBP : 1000 groups Alarms : 200 groups Holographic waveform : 1 hour |
Dimension | 280 × 420 × 480 mm |
Weight | 5 Kgs |
Light Source | 8 Blue LED lights |
Wavelength | 450 to 475nm |
LED Lamp-life | 1,00,000 hours |
Intensity Control | Low : 25 ~ 35 μW /cm2/nm High : 35 ~ 55 μW /cm2/nm |
Display Size | 2.4" TFT Color LCD |
Display Parameter | Treatment time, Total used time |
Timer | 30 min to 999 hrs |
Effective Exposure Area | 400 x 200 mm |
Intensity Tolerance | ±10% over 6 hours |
Stand Height | 740 mm ~ 1180 mm |
Operational Temperature | 10°C ~ 40°C |
Operational Humidity | 5 % ~ 85 % |
Audible Noise | < 60 dB |
Head Source Dimensions | 210 x 340 x 75 mm |
Power | 100 ~ 240V (50/60Hz) |
Weight | 13 Kgs |
Type | Adult |
Stroke volume | 800 ml |
Resuscitator volume | 1630 ml |
Bag reservoir volume | 2000 ml |
Pressure | 60 cmH2O |
Patient weight | ≥ 33 kg |
Dead space (patient valve) | 7 ml |
Dimensions (L × D) | 325 × 132 mm |
Type | Pediatric |
Stroke volume | 350 ml |
Resuscitator volume | 680 ml |
Bag reservoir volume | 1600 ml |
Pressure | 40 cmH2O |
Patient weight | 10 kg ~ 33 kg |
Dead space (patient valve) | 7 ml |
Dimensions (L × D) | 262 × 105 mm |
Type | Neonatal |
Stroke volume | 150 ml |
Resuscitator volume | 250 ml |
Bag reservoir volume | 600 ml |
Pressure | 40 cmH2O |
Patient weight | ≤ 10 kg |
Dead space (patient valve) | 7 ml |
Dimensions (L × D) | 225 × 85 mm |
KVO Rate | 0.1 – 5ml/h (steps : 0.1ml/h) |
Injection Compliance | Adaptable for 5 syringe sizes |
Preset Volume Range | 0.1 ml – 1999.9 ml |
Occlusion System | 3-level alarming system |
Mechanical Precision | ≤ ±2 % |
Injection Rate Range | 50 ml Syringe : 0.1 ml – 999.9 ml/h (step: 0.1 ml/h) 1000 ml – 1800 ml/h (step: 1 ml/h) 30 ml Syringe : 0.1 ml – 900 ml/h (step: 0.1 ml/h) 20 ml Syringe : 0.1 ml – 600 ml/h (step: 0.1 ml/h) 10 ml Syringe : 0.1 ml – 300 ml/h (step: 0.1 ml/h) 5 ml Syringe : 0.1 ml – 150 ml/h (step: 0.1 ml/h) |
Purge Rate | 50 ml Syringe : 1800 ml/h (Bolus rate: 1200 ml/h) 30 ml Syringe : 900 ml/h (Bolus rate: 600 ml/h) 20 ml Syringe : 600 ml/h (Bolus rate: 400 ml/h) 10 ml Syringe : 300 ml/h (Bolus rate: 200 ml/h) 5 ml Syringe : 150 ml/h (Bolus rate: 100 ml/h) |
Occlusion Alarm Threshold | High : 800 mmHg ± 200 mmHg (106.7 kPa ± 26.7 kPa) Medium : 500 mmHg ± 100 mmHg (66.7 kPa ± 13.3 kPa) Low : 300 mmHg ± 100 mmHg (40.7 kPa ± 13.3 kPa) |
Fuse | F1AL/250V (2 nos.) |
Power Supply | 100 V – 220 V, 50 Hz |
Battery | Built–in Rechargeable Li–ion battery (11.1V) Capacity ≥ 2000mAh ; 10 hours of charging Works at 5ml/h after 4 hours of charging |
Alarm | Near Injection finished, Preset dose injection finished, Occlusion, Syringe off, Syringe dislocated, Low Battery, On AC Supply. |
Safety | Class I Type BF |
Operation | Ambient Temperature : 5°C to 40°C Relative Humidity : 20% – 90% Atmospheric Pressure : 86 kPa – 106 kPa |
Storage | Ambient Temperature : –30°C to 55°C Relative Humidity : ≤ 95% Atmospheric Pressure : 50 kPa – 106 kPa |
Dimensions | 282 x 210 x 148 mm |
Weight | 2 Kgs |
Channel | Single channel infusion |
Volume (VTBI) | 0 ml – 9999 ml |
Injection Compliance | Adaptable for 6 syringe sizes |
Accuracy | ≤ ±2 % |
KVO Rate | 0.01 ml/h – 5 ml/h (steps : 0.01 ml/h) |
Occlusion System | 12 selectable occlusion levels |
Syringe Size | 5 ml, 10 ml, 20 ml, 30 ml, 50 ml, 60 ml |
Infusion Mode | Rate mode/Time mode, Body weight, TIVA, Relay mode Loading-dose, Ramp up/down, Sequence, Drug library mode, Micro mode |
Flow Selection | 0.01 ml/h ~ 1500 ml/h, increment 0.01 ml/h |
Bolus Rate | 0.1 ml/h ~ 1500 ml/h (Auto or Manual bolus control) |
Display | 4.3-inch colour LCD screen |
Battery | Lithium polymer battery 11.1 V 2600 mAh About 12 hours of operation at 5ml/h (< 5 hours of charging) |
Memory | Records over 5000 entries for review |
Drug library | Database of up to 2000 drugs |
Safety | Class I Type CF |
Moisture Protection | IP24 |
Operation | Ambient Temperature: 5 °C to 40 °C Relative Humidity: 20 % to 90 % |
Storage | Ambient Temperature: –30 °C to 55 °C Relative Humidity: ≤ 95% |
Power Supply | AC : 110 V ~ 240 V, 50/60 Hz DC : 12 V |
Dimensions | 235 × 90 × 120 mm |
Weight | 1.7 kgs |
Channel | Dual channel infusion |
Volume (VTBI) | 0.1 ml – 1999.9 ml |
Injection Compliance | Adaptable for 10 syringe sizes |
Accuracy | ≤ ± 3 % |
KVO Rate | 0.1 ml/h – 5 ml/h (steps : 0.1 ml/h) |
Occlusion System | 3 selectable occlusion levels |
Infusion Rate | 0.1 ml/h ~ 1600 ml/h, increment 0.1ml/h |
Syringe Size | Channel 01 : 5 ml / 10 ml / 20ml / 30ml / 50ml Channel 02 : 6 ml / 12 ml / 25 ml / 35 ml / 60 ml |
Bolus | Syringe 50 ml: 1600 ml/h Syringe 30 ml: 900 ml/h Syringe 20 ml: 600 ml/h Syringe 10 ml: 400 ml/h Syringe 5 ml: 200 ml/h |
Occlusion Alarm Threshold | High: 110 kPa ± 20 kPa (825 mmHg ± 150 mmHg) Medium: 80 kPa ± 30 kPa (600 mmHg ± 225 mmHg) Low: 60 kPa ± 20 kPa (450 mmHg ± 150 mmHg) |
Display | 4.3” color segment LCD screen |
Environmental conditions : Operation | Ambient Temperature: 5 °C to 40 °C Relative Humidity: 20 % to 90 % Atmospheric Pressure: 86 kPa to 106 kPa |
Environmental conditions : Storage | Ambient Temperature: –30 °C to 55 °C Relative Humidity: ≤ 95% Atmospheric Pressure: 50 kPa – 106 kPa |
Alarm | Occlusion, nearly finish, finish, standby (no operation), low battery, battery exhausted |
Power Supply | 100 V ~ 240 V, 50 Hz / 60 Hz |
Power Consumption | ≤ 25 VA |
Safety | Class I Type CF |
Dimensions | 354 × 132 × 199 mm |
Weight | 2.8 kg |
Tidal Volume | 0 ml – 1500 ml |
Gas Supply | O2, 0.28 to 0.6 MPa |
Ventilation Modes | A/C, SIMV, SPONT, Manual, VCV+SIGH |
Respiratory Rate | 4 bpm – 40 bpm (SIMV) 4 bpm – 99 bpm (A/C) |
Range Of I:E Ratio | 2:1 to 1: 4 |
FiO2 Range | 48% to 100% |
Pressure Sensitivity | Above PEEP: - 2 kPa to 0 kPa PEEP: 0.5 kPa to 2 kPa |
Pressure Parameter | Ppeak |
Volume/Flow Parameter | Vt , MV |
Time Parameter | Ftotal |
Real-Time Curves | Pressure-Time |
Compliance | < 4 ml/100 Pa |
Cylinder Capacity | 3.2 L |
Max. Pressure | < 6 kPa |
Battery Life | 4 Hours of Uninterrupted Battery life |
Environmental Temperature | Operation: -10°C to 50°C Storage: -20°C to 55°C |
Relative Humidity | Operation: < 85 % Storage: < 93 % |
Atmospheric Pressure | Operation: 70 kPa – 110 kPa Storage: 50 kPa – 110 kPa |
Power Supply | 110 V - 220 V, 50/60Hz , < 65 VA |
Dimensions | 175 x 170 x 300 mm |
Weight | 3.5 Kgs |