Type Fully Automated Analysis system
Throughput 140 tests per hour
Analytical Methods End point, Kinetic, fixed time, Bi-chromatic, multi-standard, Two steps of end point and more
Assay Modules Over 200 modules
Sample Slots 64 slots for standard and control
Sample Volume 1-100ul, 1ul / step
Reaction tray size 96 reaction cuvettes
Flow cell volume 32 ul
Reagent Diluter : 1000ul, 1ul/step
Reagent Slots
Photometric Measuring range 0.0 – 3.0 OD (filters)
Reagent Volume
Probe Handling With liquid sensor & automatic probe washing and crash function
Washing Reaction Cuvettes Automatic Flow cell washing
Data Transmission USB 2.0
Reaction Time
Alarms Reagent / sample alarm, Water alarm, Hit the needle alarm, Replace the reaction plate
Calibration System Calibration : Deduction of washer blank/ reagent blank
Nonlinear linear or with 1-6 calibration standards
Lamp 7 high-quality 6 V/ 10 W Halogen lamp
Storage Up to millions of analysis reports
Absorbance Resolution
Absorbance Accuracy
Repeatability
Quality Control Levy-Jennings chart and West guard analysis 
Power Supply 220 V / 50 Hz or 110 V / 60 Hz
Dimension 600 x 500 x 410 mm
Weight
Type Fully Automated Random Access System
Throughput Reagent 1 : 400 test/hr
Reagent 2 : 600 test/hr
With ISE : 400 test/hr
Analytical Methods End-point, Multi-standard, Immuno-turbid metric, 1-2 reagent, Reagent/serum blank, etc.
Assay Modules 80 modules
Sample Slots 80
Sample Volume 1µL - 100µL, (0.1µL/step)
Reaction tray size
Flow cell volume
Reagent
Reagent Slots 2 x 40
Photometric Measuring range
Reagent Volume R1 : 1µL - 400µL, (1µL/step)
R2 : 1µL - 400µL, (1µL/step)
1µL - 500µL, (0.1µL/step) [Min. 50 µL/test on request]
Probe Handling Liquid level sensor, Collision sensor, Teflon coating and Automatic washing station.
Washing Reaction Cuvettes 8 channel Auto-washing
Data Transmission
Reaction Time 0 s – 999 s
Alarms Auto-alarm for crucial events (collision, reagent/ sample insufficiency, full waste container, etc.)
Calibration Linear, Non-linear, Multi-point, K factor
Lamp Halogen Lamp
Wavelength : 340 nm – 810 nm
Storage
Absorbance Resolution 0.0001 Abs
Absorbance Accuracy ± 0.0003 Abs ; ( 0 Abs – 2.5 Abs)
Repeatability ≤ 2 %
Quality Control Levy-Jennings quality control at 3 levels
Power Supply 220 V / 50 Hz or 110 V / 60 Hz
Dimension 1000 x 850 x 700 mm
Weight 137 Kgs
Type Fully Automatic Random Access system
Throughput 120 tests/hour
Assay Modules Up to 26 Assays
Sample slots 9
Sample volume 3 µL – 45 µL, (0.5 µL step adjustability)
Reagent slots 26
Reagent volume R1 : 180 µL – 450 µL, (1 µL step adjustability)
R2 : 180 µL – 450 µL, (1 µL step adjustability)
Reaction slots 90 cuvettes, 10 cuvettes/strips
Cuvette (Optical length) 5 mm
Reaction volume 180 µL – 500 µL
Reaction temperature (37° ± 0.4°) C
Probe Handling Pre-heat, Collision protection, Liquid-level detection, Inventory checking, Automatic inner and outer probe washing
Lamp Halogen bulb
Absorbance range (0 Abs – 3.500 Abs) ± 1 %
Wavelength 340 nm – 700 nm
Resolution 0.0001 Abs
Temperature 10°C - 35°C
Humidity 35% – 80%
Reagent refrigeration 4°C - 15°C
Water Consumption 1.5 L/hr
Power Supply 100 V – 240 V ; 50/60 Hz
Dimension 583 x 453 x 530 cm
Weight 70 Kgs
Number of channels Single channel
Test parameters PT [Prothrombin Time]
APTT [Activated Partial Thromboplastin Time]
TT [Thrombin Time]
FBG [Fibrinogen Concentration]
Clotting Factors
Measurement method Photometric analysis
Display Back-illuminated LCD
Reagent volume 50 µl ~ 100µl
Pre-heat temperature 37 ± 0.2 °C
Capacity Sample: 16 positions
Reagent: 2 positions
Storage Large storage memory and user-friendly review system
Output interface Built-in thermal printer
Power supply 110V / 60Hz
220V / 50Hz
Stirring Automated magnetic stirring motor for cuvette
Dimension 310 X 200 X 280 mm
Weight 4.5 Kgs
Measurement range 3 % ~ 18 %
Testing parameters Precision (CV) < 3 %
Accuracy (V) < 1.5 %
Sample type Venous blood (EDTA anticoagulation), Peripheral finger blood
Sample volume 5 µl whole blood for each sample
Photometer 415 nm LED integral flow colorimeter
Sampling mode (20 samples) position 2 quality control position
1 emergency position
1 cleaning position
1 zero position
Test mode Automated sample batch test
Single sample test
Calibration 2 points or 4 points calibration,
Manual or automation with a set of calibrators
Thermostatic control 25 ± 0.5°C (column and reagent thermostatic control)
Reagent matching Column and reagent consumable / 300 pieces of testing sample
Reagent allocation A, B, C, D eluent, calibrator, hemolytic agent, pump tubing
Display 320 x 240 LCD graphic display for real-time testing curve
Printer 58mm Thermal printer, printing testing curve and report
Report output IFCC concentration value
NGSP area percentage
ADAG average glucose
Data storage 1000 tests report (including testing curve)
Interface RS-232 interface
HIS/LIS system interface
Power supply AC 220V / 50Hz
Working environment Temperature: 12°C ~ 30°C
Relative Humidity: < 85 %
Dimensions 408 x 390 x 230 mm
Weight 9 Kgs
Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
Accuracy (CV %) WBC (109/L) : 2.0 % (7.0 - 15.0)
RBC (1012/L) : 1.5 % (3.50 - 6.00)
HGB (g/L) : 1.5 % (110 - 180)
MCV (fL) : 0.4 % (80.0 - 110.0)
PLT (109/L) : 4 % (100 - 500)
Linear Range
Sample Mode
Test Mode
Screen Display 8.4” display color LCD
Resolution 640 x 480
Sample Volume Pre-diluted : 20 µL
Whole blood : 9.8 μL
Reagents
Aperture Diameter WBC : 80µm
RBC : 50µm
Carryover WBC / RBC / HGB <0.5 % PLT<1.0 %
QC
Connectivity LAN, USB, RS-232
Printer Built-in Thermal printer
Storage 35,000 records
Operating Temperature 15 °C to 35 °C
Humidity 10 % - 90 %
Maintenance
Power Supply AC 110 V – 220 V, 50 / 60 Hz
Dimensions 436 x 363 x 367 mm
Weight 18 Kgs
Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
Accuracy (CV %) WBC (109/L) : 2.0 % (7.0 - 15.0)
RBC (1012/L) : 1.5 % (3.50 - 6.00)
HGB (g/L) : 1.5 % (110 - 180)
MCV (fL) : 0.4 % (80.0 - 110.0)
PLT (109/L) : 4 % (100 - 500)
Linear Range
Sample Mode
Test Mode
Screen Display 10.4” TFT color touch LCD
Resolution 640 x 480
Sample Volume Pre-diluted : 20 µL
Whole blood : 9.8 μL
Reagents
Aperture Diameter WBC : 80µm
RBC : 50µm
Carryover WBC / RBC / HGB <0.5 % PLT<1.0 %
QC
Connectivity LAN, USB, RS-233
Printer Built-in Thermal printer
Storage 50,000 records
Operating Temperature 15 °C to 35 °C
Humidity 0.8
Maintenance
Power Supply AC 110 V – 220 V, 50 / 60 Hz
Dimensions 436 x 363 x 367 mm
Weight 18 Kgs
Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LY, LY%, MO, MO%,GR,GR%,RBC,HGB,HCT, MCV,RDW-SD, RDWCV, MCH, MCHC, PLT, MPV, PCT, PDW with Histograms for WBC, RBC and PLT.
Accuracy (CV %) WBC ≤ 2.0 %
RBC ≤ 1.5 %
PCT ≤ 3.0 %
PLT ≤ 5.0 %
HGB ≤ 1.5 %
MCV ≤ 1.0 %
MPV ≤ 3.0 %
PDW ≤ 3.0 %
MCH ≤ 2.0 %
MCHC ≤ 2.0 %
Linear Range
Sample Mode
Test Mode
Screen Display LCD display screen
Resolution
Sample Volume Pre-diluted : 20 µL
Whole blood : 13 μL
Reagents
Aperture Diameter
Carryover
QC
Connectivity RS-232, PS-2, USB and LIS
Printer Built-in Thermal printer
Storage 2,00,000 records
Operating Temperature
Humidity
Maintenance
Power Supply AC 110 V – 220 V, 50 / 60 Hz
Dimensions 430 x 320 x 505 mm
Weight 20 Kgs
Type Fully automated 5-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%, ALY#, ALY%, IG#, IG%, 2 histograms, 2 scatter grams.
Accuracy (CV %) WBC (109/L) : 2.0 %
RBC (1012/L) : 1.5 %
HGB (g/L) : 1.5 %
PLT (109/L) : 4 %
Linear Range WBC (109/L) : 1.0 – 99.9
RBC (1012/L) : 0.3 – 7.0
HGB (g/L) : 20 – 24
PLT (109/L) : 20 – 999
Sample Mode Pre-diluted
Whole blood
Test Mode CBC+5DIFF test
CBC test
Screen Display
Resolution
Sample Volume
Reagents
Aperture Diameter
Carryover WBC / RBC / HGB <0.5 % PLT<1.0 %
QC
Connectivity LIS interface with HL7
Printer Built-in Thermal printer
Storage 1,00,000 records
Operating Temperature 15 °C to 30 °C
Humidity 30 % - 85 %
Maintenance
Power Supply AC 110 V – 220 V, 50 / 60 Hz
Dimensions 460 x 570 x 610 mm
Weight 53 Kgs
Type Fully automated 3-part differential system
Throughput 30 samples/hr
Principle of Operation Impedance, SFT method
Testing Parameters
Accuracy (CV %) WBC(109/L) : 2.0 %
RBC (1012/L) : 1.5 %
HGB (g/L) : 1.5 %
MCV (fL) : 0.5 %
PLT (109/L) : 4.0 %
Linear Range
Sample Mode Pre-diluted
Whole blood
Test Mode
Screen Display High resolution large color LCD
Resolution 800 x 600
Sample Volume Pre-diluted : 20 µL
Whole blood : 9 - 20 µL
Reagents Non-toxic cyanide-free reagents
Aperture Diameter
Carryover
QC
Connectivity RS232, USB
Printer Built-in Thermal printer
Storage 35,000 records with 3 histograms
Operating Temperature 10 °C to 30 °C
Humidity 0.7
Maintenance Auto reverse flush and high voltage burning, clog clearing
Power Supply AC 100 V – 240 V, 50 / 60 Hz
Dimensions 273 × 420 × 415 mm
Weight 16 Kgs
Type Fully automated 5-part differential system
Throughput 60 samples/hr
Principle of Operation Impedance, Colorimetry
Testing Parameters
Accuracy (CV %) WBC (109/L) : (0 - 100)
RBC (1012/L) : (0 - 1700)
HGB (g/L) : (0 - 250)
PLT(109/L) : (0 - 3000)
Linear Range
Sample Mode Pre-diluted
Whole blood
Test Mode
Screen Display 10.4” display color touchscreen LCD
Resolution 801 x 600
Sample Volume Pre-diluted : 20 µL
CBC + Diff mode : 20 µL
Reagents 3 (2 Lyses + 1 Diluent) and 1PB cleanser
Aperture Diameter
Carryover
QC 3 level LJ graph, XB
Connectivity 1 LAN, 4 USB, HL7 protocol, LIS compliant
Printer Built-in Thermal printer
Storage 60,000 records with 4 scatter grams and 2 histograms
Operating Temperature 10 °C to 30 °C
Humidity
Maintenance High voltage, High pressure flush and Auto cleaning of probes
Power Supply AC 100 V – 240 V, 50 / 60 Hz
Dimensions 430 x 350 x 435 mm
Weight 33 Kgs
Method RGB Tricolor test
Test mode Single-step test
Strip compliance 8, 10, 11, 12, 14 parameter test strips
Memory Stores up to 500 records
Repeatability CV ≤ 1%
Stability CV ≤ 1%
Display 2.4-inch LCD (320 x 240 resolution)
Interface Micro USB interface
Record mode Flash ROM data storage
Power 100 V – 240 V, 50 / 60 Hz
Power consumption ≤ 5 W
Battery Rechargeable Li-ion battery, 3.7 V, 1900 mAh
Dimensions 126 x 74 x 30 mm
Weight 200 g