Patient range | Adult, pediatric, neonate |
NIBP Measurement method | Oscillometric |
NIBP Measurement range | 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg) |
NIBP Measurement mode | Arm Measurement |
NIBP Measurement interval | 15, 30, 60, 120, 240 min (Auto mode ) |
NIBP - Resolution | 1 mmHg |
NIBP - Accuracy | ± 3 mmHg |
Pulse Rate Measurement range | 40 bpm – 240 bpm |
Pulse rate - Resolution | 1 bpm |
Pulse rate - Display | 2.4” color TFT – LCD |
Power Supply | DC : 3 V |
Alarm | SYS, DIA (User defined) |
Storage | Auto mode : up to 350 results Manual mode : up to 300 results |
Dimension | 128 × 69 × 36 mm |
Weight | < 300 g |
Display | 12.1” LCD display |
Ultrasound frequency | 1024 (1 ± 10%) kHz |
Max output intensity | < 10 MW/cm2 |
FHR measurement range | 30 bpm ~ 240 bpm |
FHR sensitivity | ≤ 2 bpm |
FHR alarm range | 30 bpm ~ 240 bpm |
Alarm time | ≤ 30s |
Alarm limits | FHR Higher [User defined] FHR Lower [User defined] TOCO Higher [User defined] TOCO Lower [User defined] |
TOCO measurement range | 0 ~ 100 units |
TOCO baseline | 0 ~ 20 units |
TOCO sensitivity | ≤ 10 % |
Recorder paper speed | 1,2,3 cm/min |
Recorder deviation | ≤ 5 % |
Print duration | 5 min – 240 min |
Safety standard | Class I, BF type |
Storage temperature range | 40℃ ~ 55℃ |
Storage relative humidity | ≤ 93 % |
Storage pressure range | 500 hPa ~ 1060hPa |
Operational temperature range | 10°C ~ 40°C |
Relative humidity | ≤ 80 % |
Atmosphere pressure | 70 kPa ~ 106 kPa |
Weight | 4.5 Kgs |
Display | OLED 160 x 128 dot matrix display |
Storage | Built-in TF card storage for up to 2 GB |
Standard Sensitivity | 10 mm/mV ± 5% |
Sensitivity Shift | ≤ ± 10% |
Channel Display | 12 Channel |
Scan Speed | 25 mm/s ± 5% |
Pacing Analysis | Dual chamber pacing, Atrial pacing, Ventricular pacing module Ventricular Pseudofusion and Ventricular asynchronous module |
Arrhythmia Analysis | MCSSTM and TMCATM |
ECG-Analysis | ST segment analysis , HRT analysis, T-Wave alternation,QTD (QT dispersion) VCG (vector cardiogram), VLP (ventricular late potential) and TVCG (time vector cardiogram) analysis |
Heart-rate Analysis | Short range : 5 minutes Long range : 1 hour Continuous : 24 hours |
Sampling | Sampling Accuracy : 12 Bit Rate of Sampling : 10 kHz |
Batteries | 2 AA batteries |
Interface | USB 2.0 |
Scale Voltage | 1mV ± 5% |
Noise | ≤ 30µV |
CMRR | ≥ 60 dB |
Time Constant | ≥ 3.2 s |
Polarization voltage | ± 300 mV (DC) |
Dimension | 111 x 60 x 25 mm |
Weight | 105 g |
Vital Parameters |
|
||||||
Display | 240 x 320 dot matrix colour TFT | ||||||
NIBP Measurement range | Adult: 30-255 mmHg Paediatric: 30-160 mmHg | ||||||
NIBP Mode | Auto, Manual, STAT | ||||||
NIBP Parameters | SYS, DIA, MAP | ||||||
NIBP interval | Auto mode: 1, 2 , 3, 5, 10, 15, 20, 25, 30, 45, 60 mins STAT mode: 5 mins | ||||||
Resolution | 1 mmHg | ||||||
NIBP Over-pressure protection | Adult: 300 mmHg Pediatric: 22 mmHg | ||||||
SpO2 Measurement range | 0 - 100% | ||||||
SpO2 Accuracy | ±2% (90-100)%, ±3% (70-89)%, <70% (unspecified) | ||||||
SpO2 Resolution | 0.01 | ||||||
PR Measurement range | 30 bpm - 250 bpm | ||||||
PR Accuracy | ±1 bpm | ||||||
PR Resolution | 1bpm | ||||||
Temp Probe | Body sensitive temperature sensor | ||||||
Temp Measurement range | 0⁰C to 50⁰C | ||||||
Temp Accuracy | ± 0.1⁰C | ||||||
Temp Resolution | 0.1⁰C | ||||||
Graphic LCD size | 44 x 59 mm | ||||||
Audio-visual Alarms | Sensor-off alarm, Measurement out of user-defined limits | ||||||
Data Transmission | USB-based transmission to PC Internet-based tele monitoring | ||||||
Operational Temperature | 0⁰C to 45⁰C | ||||||
Relative Humidity | 15% to 95% | ||||||
Pressure | 86 kPa – 106 kPa | ||||||
Power Supply | Input power: AC 100-240V, 50-60Hz, 0.7A Output power: 5V,2.5A | ||||||
Battery | 2.8 A built-in rechargeable Li-ion battery Run Time : 5 hours Charging Time : 8 hours |
Vital Parameters | 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP) |
NIBP Measurement range | Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg |
NIBP Mode | Manual, Auto |
NIBP Parameters | Sys, Dia, MAP |
NIBP interval | Auto Mode: 1 ~ 240 min, < 10 s |
NIBP Over-pressure protection | Adult: 300 mmHg Child: 140 mmHg |
SpO2 Measurement range | 35 % ~ 100 % |
SpO2 Accuracy | 75 % ~ 100 % @ ± 2 % 35 % ~ 74 % @ ± 3 % |
PR Measurement range | 30 bpm ~ 250 bpm |
PR Accuracy | ±2 bpm |
TEMP Monitoring range | 21 ⁰C ~ 50 ⁰C |
TEMP Monitoring accuracy | ±0.1 ⁰C |
TEMP Responding time | ≤ 150 s |
Recording speed | 25 mm/s |
Recording speed accuracy | ≤ 5% |
Power Supply | AC 100-250V, 50-60Hz |
Battery | 12 V, 2.3 AH (Lead-acid battery) |
Standard Parameter | 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR |
Patient Groups | Neonate, Pediatric, Adults |
Trace | 9 waveform (ECG,SpO2, RESP) |
ECG Lead Mode | 5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL |
ECG Waveform | 3 and 7 channel selectable |
ECG Gain selection | 0.5mm/mv 1mm/mv 2mm/mv |
ECG Sweep Speed | 12.5 mm/s 25 mm/s 50 mm/s |
Heart Rate range | Adult : 15 ~ 300 bpm Neonate /Pediatric : 15 bpm ~ 350 bpm Alarm range : 15 ~ 350 bpm |
ECG Accuracy | +1 bpm |
ECG Resolution | 1 bpm |
Protection | withstands 4000VAC/50 voltage isolation |
S‐T segment analysis | Range : -2.0 mV ~ +2.0 mV Accuracy: ‐0.8mV ~ +0.8mv Error: +0.02Mv |
Arrhythmia analysis | |
Scaling | 1mv, +3% |
SpO2 Measurement range | 0% ~ 100% Alarm range : 0% ~ 100% |
SpO2 Accuracy | ±2 % (70 % – 100 %) 0 – 69% unspecified |
SpO2 Pulse Rate | Range : 20bpm ~ 300bpm Resolution: 1bpm Error: +1bpm |
NIBP Method | Digital Automatic Oscillometric |
NIBP Operation Mode | Manual/Automatic/Continuous for Systolic, Diastolic and Mean |
Auto Measurement | Adjustable Duration : 1 ~ 480 mins |
Range Of Systolic Pressure | Adult: 40 ~ 270mmHg Pediatric: 40 ~ 220mmHg Neonate: 40 ~ 135 mmHg |
Range Of Diastolic Pressure | Adult: 10 ~ 215 mmHg Pediatric: 10 ~ 150 mmHg Neonate :10 ~ 100 mmHg |
Over‐pressure Protection | Double safety protection |
Respiratory Method | Thoracic impedance |
Respiratory Measurement range | Adult: 7 ~ 120 rpm Neonate/Pediatric: 7 ~ 150 rpm |
Apnea Alarm | 10s ~ 40s |
Respiratory Resolution | 1 rpm |
Respiratory Accuracy | ±2 bpm |
Temp Measurement range | 5 ℃ ~ 50 ℃ |
Average Measuring Time | < 10 sec |
Temp Resolution | 0.1℃ |
Temp Accuracy | ± 0.1℃ |
Display | 12.1’’color TFT |
Resolution | 800 x 600 dot pixels |
Trend | 5 s/piece, 8 hours 5min/piece, 1000 hours |
Alarm | User‐adjustable 3‐level Audio-visual alarm. |
Safety Standard | Class I, type CF |
Working Temperature | 0 ~ 40℃ |
Relative Humidity | ≤ 85 % |
Power Supply | AC 100 ‐ 240 V, 50/60 Hz |
Battery | Rechargeable Lead acid cell, 12 V/4 Ah |
Storage | NIBP : 1000 groups Alarms : 200 groups Holographic waveform : 1 hour |
Dimension | 280 × 420 × 480 mm |
Weight | 5 Kgs |