Type | Fully automated 3-part differential system |
Throughput | 60 samples/hr |
Principle of Operation | |
Testing Parameters | WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT. |
Accuracy (CV %) | WBC (109/L) : 2.0 % (7.0 - 15.0) RBC (1012/L) : 1.5 % (3.50 - 6.00) HGB (g/L) : 1.5 % (110 - 180) MCV (fL) : 0.4 % (80.0 - 110.0) PLT (109/L) : 4 % (100 - 500) |
Linear Range | |
Sample Mode | |
Test Mode | |
Screen Display | 8.4” display color LCD |
Resolution | 640 x 480 |
Sample Volume | Pre-diluted : 20 µL Whole blood : 9.8 μL |
Reagents | |
Aperture Diameter | WBC : 80µm RBC : 50µm |
Carryover | WBC / RBC / HGB <0.5 % PLT<1.0 % |
QC | |
Connectivity | LAN, USB, RS-232 |
Printer | Built-in Thermal printer |
Storage | 35,000 records |
Operating Temperature | 15 °C to 35 °C |
Humidity | 10 % - 90 % |
Maintenance | |
Power Supply | AC 110 V – 220 V, 50 / 60 Hz |
Dimensions | 436 x 363 x 367 mm |
Weight | 18 Kgs |
Type | Fully automated 3-part differential system |
Throughput | 60 samples/hr |
Principle of Operation | |
Testing Parameters | WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT. |
Accuracy (CV %) | WBC (109/L) : 2.0 % (7.0 - 15.0) RBC (1012/L) : 1.5 % (3.50 - 6.00) HGB (g/L) : 1.5 % (110 - 180) MCV (fL) : 0.4 % (80.0 - 110.0) PLT (109/L) : 4 % (100 - 500) |
Linear Range | |
Sample Mode | |
Test Mode | |
Screen Display | 10.4” TFT color touch LCD |
Resolution | 640 x 480 |
Sample Volume | Pre-diluted : 20 µL Whole blood : 9.8 μL |
Reagents | |
Aperture Diameter | WBC : 80µm RBC : 50µm |
Carryover | WBC / RBC / HGB <0.5 % PLT<1.0 % |
QC | |
Connectivity | LAN, USB, RS-233 |
Printer | Built-in Thermal printer |
Storage | 50,000 records |
Operating Temperature | 15 °C to 35 °C |
Humidity | 0.8 |
Maintenance | |
Power Supply | AC 110 V – 220 V, 50 / 60 Hz |
Dimensions | 436 x 363 x 367 mm |
Weight | 18 Kgs |
Type | Fully automated 3-part differential system |
Throughput | 60 samples/hr |
Principle of Operation | |
Testing Parameters | WBC, LY, LY%, MO, MO%,GR,GR%,RBC,HGB,HCT, MCV,RDW-SD, RDWCV, MCH, MCHC, PLT, MPV, PCT, PDW with Histograms for WBC, RBC and PLT. |
Accuracy (CV %) | WBC ≤ 2.0 % RBC ≤ 1.5 % PCT ≤ 3.0 % PLT ≤ 5.0 % HGB ≤ 1.5 % MCV ≤ 1.0 % MPV ≤ 3.0 % PDW ≤ 3.0 % MCH ≤ 2.0 % MCHC ≤ 2.0 % |
Linear Range | |
Sample Mode | |
Test Mode | |
Screen Display | LCD display screen |
Resolution | |
Sample Volume | Pre-diluted : 20 µL Whole blood : 13 μL |
Reagents | |
Aperture Diameter | |
Carryover | |
QC | |
Connectivity | RS-232, PS-2, USB and LIS |
Printer | Built-in Thermal printer |
Storage | 2,00,000 records |
Operating Temperature | |
Humidity | |
Maintenance | |
Power Supply | AC 110 V – 220 V, 50 / 60 Hz |
Dimensions | 430 x 320 x 505 mm |
Weight | 20 Kgs |
Type | Fully automated 5-part differential system |
Throughput | 60 samples/hr |
Principle of Operation | |
Testing Parameters | WBC, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%, ALY#, ALY%, IG#, IG%, 2 histograms, 2 scatter grams. |
Accuracy (CV %) | WBC (109/L) : 2.0 % RBC (1012/L) : 1.5 % HGB (g/L) : 1.5 % PLT (109/L) : 4 % |
Linear Range | WBC (109/L) : 1.0 – 99.9 RBC (1012/L) : 0.3 – 7.0 HGB (g/L) : 20 – 24 PLT (109/L) : 20 – 999 |
Sample Mode | Pre-diluted Whole blood |
Test Mode | CBC+5DIFF test CBC test |
Screen Display | |
Resolution | |
Sample Volume | |
Reagents | |
Aperture Diameter | |
Carryover | WBC / RBC / HGB <0.5 % PLT<1.0 % |
QC | |
Connectivity | LIS interface with HL7 |
Printer | Built-in Thermal printer |
Storage | 1,00,000 records |
Operating Temperature | 15 °C to 30 °C |
Humidity | 30 % - 85 % |
Maintenance | |
Power Supply | AC 110 V – 220 V, 50 / 60 Hz |
Dimensions | 460 x 570 x 610 mm |
Weight | 53 Kgs |
Type | Fully automated 3-part differential system |
Throughput | 30 samples/hr |
Principle of Operation | Impedance, SFT method |
Testing Parameters | |
Accuracy (CV %) | WBC(109/L) : 2.0 % RBC (1012/L) : 1.5 % HGB (g/L) : 1.5 % MCV (fL) : 0.5 % PLT (109/L) : 4.0 % |
Linear Range | |
Sample Mode | Pre-diluted Whole blood |
Test Mode | |
Screen Display | High resolution large color LCD |
Resolution | 800 x 600 |
Sample Volume | Pre-diluted : 20 µL Whole blood : 9 - 20 µL |
Reagents | Non-toxic cyanide-free reagents |
Aperture Diameter | |
Carryover | |
QC | |
Connectivity | RS232, USB |
Printer | Built-in Thermal printer |
Storage | 35,000 records with 3 histograms |
Operating Temperature | 10 °C to 30 °C |
Humidity | 0.7 |
Maintenance | Auto reverse flush and high voltage burning, clog clearing |
Power Supply | AC 100 V – 240 V, 50 / 60 Hz |
Dimensions | 273 × 420 × 415 mm |
Weight | 16 Kgs |
Type | Fully automated 5-part differential system |
Throughput | 60 samples/hr |
Principle of Operation | Impedance, Colorimetry |
Testing Parameters | |
Accuracy (CV %) | WBC (109/L) : (0 - 100) RBC (1012/L) : (0 - 1700) HGB (g/L) : (0 - 250) PLT(109/L) : (0 - 3000) |
Linear Range | |
Sample Mode | Pre-diluted Whole blood |
Test Mode | |
Screen Display | 10.4” display color touchscreen LCD |
Resolution | 801 x 600 |
Sample Volume | Pre-diluted : 20 µL CBC + Diff mode : 20 µL |
Reagents | 3 (2 Lyses + 1 Diluent) and 1PB cleanser |
Aperture Diameter | |
Carryover | |
QC | 3 level LJ graph, XB |
Connectivity | 1 LAN, 4 USB, HL7 protocol, LIS compliant |
Printer | Built-in Thermal printer |
Storage | 60,000 records with 4 scatter grams and 2 histograms |
Operating Temperature | 10 °C to 30 °C |
Humidity | |
Maintenance | High voltage, High pressure flush and Auto cleaning of probes |
Power Supply | AC 100 V – 240 V, 50 / 60 Hz |
Dimensions | 430 x 350 x 435 mm |
Weight | 33 Kgs |