Welcome LABWARE DEALS LAB EQUIPMENT CO., INC
Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
Accuracy (CV %) WBC (109/L) : 2.0 % (7.0 - 15.0)
RBC (1012/L) : 1.5 % (3.50 - 6.00)
HGB (g/L) : 1.5 % (110 - 180)
MCV (fL) : 0.4 % (80.0 - 110.0)
PLT (109/L) : 4 % (100 - 500)
Linear Range
Sample Mode
Test Mode
Screen Display 8.4” display color LCD
Resolution 640 x 480
Sample Volume Pre-diluted : 20 µL
Whole blood : 9.8 μL
Reagents
Aperture Diameter WBC : 80µm
RBC : 50µm
Carryover WBC / RBC / HGB <0.5 % PLT<1.0 %
QC
Connectivity LAN, USB, RS-232
Printer Built-in Thermal printer
Storage 35,000 records
Operating Temperature 15 °C to 35 °C
Humidity 10 % - 90 %
Maintenance
Power Supply AC 110 V – 220 V, 50 / 60 Hz
Dimensions 436 x 363 x 367 mm
Weight 18 Kgs
Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LYM#, MON#, GRA#, LYM%,MON%, GRA%, RBC, HGB, MCHC, MCH, MCV, PDW, RDW-CV, RDW-SD, HCT, PLT,MPV, P-LCR, PCT with Histograms for WBC, RBC and PLT.
Accuracy (CV %) WBC (109/L) : 2.0 % (7.0 - 15.0)
RBC (1012/L) : 1.5 % (3.50 - 6.00)
HGB (g/L) : 1.5 % (110 - 180)
MCV (fL) : 0.4 % (80.0 - 110.0)
PLT (109/L) : 4 % (100 - 500)
Linear Range
Sample Mode
Test Mode
Screen Display 10.4” TFT color touch LCD
Resolution 640 x 480
Sample Volume Pre-diluted : 20 µL
Whole blood : 9.8 μL
Reagents
Aperture Diameter WBC : 80µm
RBC : 50µm
Carryover WBC / RBC / HGB <0.5 % PLT<1.0 %
QC
Connectivity LAN, USB, RS-233
Printer Built-in Thermal printer
Storage 50,000 records
Operating Temperature 15 °C to 35 °C
Humidity 0.8
Maintenance
Power Supply AC 110 V – 220 V, 50 / 60 Hz
Dimensions 436 x 363 x 367 mm
Weight 18 Kgs
Type Fully automated 3-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, LY, LY%, MO, MO%,GR,GR%,RBC,HGB,HCT, MCV,RDW-SD, RDWCV, MCH, MCHC, PLT, MPV, PCT, PDW with Histograms for WBC, RBC and PLT.
Accuracy (CV %) WBC ≤ 2.0 %
RBC ≤ 1.5 %
PCT ≤ 3.0 %
PLT ≤ 5.0 %
HGB ≤ 1.5 %
MCV ≤ 1.0 %
MPV ≤ 3.0 %
PDW ≤ 3.0 %
MCH ≤ 2.0 %
MCHC ≤ 2.0 %
Linear Range
Sample Mode
Test Mode
Screen Display LCD display screen
Resolution
Sample Volume Pre-diluted : 20 µL
Whole blood : 13 μL
Reagents
Aperture Diameter
Carryover
QC
Connectivity RS-232, PS-2, USB and LIS
Printer Built-in Thermal printer
Storage 2,00,000 records
Operating Temperature
Humidity
Maintenance
Power Supply AC 110 V – 220 V, 50 / 60 Hz
Dimensions 430 x 320 x 505 mm
Weight 20 Kgs
Type Fully automated 5-part differential system
Throughput 60 samples/hr
Principle of Operation
Testing Parameters WBC, RBC, HGB. HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, PDW, MPV, PCT, P-LCR, NEU#, NEU%, LYM#, LYM%, MON#, MON%, EOS#, EOS%, BAS#, BAS%, ALY#, ALY%, IG#, IG%, 2 histograms, 2 scatter grams.
Accuracy (CV %) WBC (109/L) : 2.0 %
RBC (1012/L) : 1.5 %
HGB (g/L) : 1.5 %
PLT (109/L) : 4 %
Linear Range WBC (109/L) : 1.0 – 99.9
RBC (1012/L) : 0.3 – 7.0
HGB (g/L) : 20 – 24
PLT (109/L) : 20 – 999
Sample Mode Pre-diluted
Whole blood
Test Mode CBC+5DIFF test
CBC test
Screen Display
Resolution
Sample Volume
Reagents
Aperture Diameter
Carryover WBC / RBC / HGB <0.5 % PLT<1.0 %
QC
Connectivity LIS interface with HL7
Printer Built-in Thermal printer
Storage 1,00,000 records
Operating Temperature 15 °C to 30 °C
Humidity 30 % - 85 %
Maintenance
Power Supply AC 110 V – 220 V, 50 / 60 Hz
Dimensions 460 x 570 x 610 mm
Weight 53 Kgs
Type Fully automated 3-part differential system
Throughput 30 samples/hr
Principle of Operation Impedance, SFT method
Testing Parameters
Accuracy (CV %) WBC(109/L) : 2.0 %
RBC (1012/L) : 1.5 %
HGB (g/L) : 1.5 %
MCV (fL) : 0.5 %
PLT (109/L) : 4.0 %
Linear Range
Sample Mode Pre-diluted
Whole blood
Test Mode
Screen Display High resolution large color LCD
Resolution 800 x 600
Sample Volume Pre-diluted : 20 µL
Whole blood : 9 - 20 µL
Reagents Non-toxic cyanide-free reagents
Aperture Diameter
Carryover
QC
Connectivity RS232, USB
Printer Built-in Thermal printer
Storage 35,000 records with 3 histograms
Operating Temperature 10 °C to 30 °C
Humidity 0.7
Maintenance Auto reverse flush and high voltage burning, clog clearing
Power Supply AC 100 V – 240 V, 50 / 60 Hz
Dimensions 273 × 420 × 415 mm
Weight 16 Kgs
Type Fully automated 5-part differential system
Throughput 60 samples/hr
Principle of Operation Impedance, Colorimetry
Testing Parameters
Accuracy (CV %) WBC (109/L) : (0 - 100)
RBC (1012/L) : (0 - 1700)
HGB (g/L) : (0 - 250)
PLT(109/L) : (0 - 3000)
Linear Range
Sample Mode Pre-diluted
Whole blood
Test Mode
Screen Display 10.4” display color touchscreen LCD
Resolution 801 x 600
Sample Volume Pre-diluted : 20 µL
CBC + Diff mode : 20 µL
Reagents 3 (2 Lyses + 1 Diluent) and 1PB cleanser
Aperture Diameter
Carryover
QC 3 level LJ graph, XB
Connectivity 1 LAN, 4 USB, HL7 protocol, LIS compliant
Printer Built-in Thermal printer
Storage 60,000 records with 4 scatter grams and 2 histograms
Operating Temperature 10 °C to 30 °C
Humidity
Maintenance High voltage, High pressure flush and Auto cleaning of probes
Power Supply AC 100 V – 240 V, 50 / 60 Hz
Dimensions 430 x 350 x 435 mm
Weight 33 Kgs