Drive | Electronically controlled, pneumatic driven |
Tidal Volume | 0 ml -1500 ml |
Configuration | Trolley / Table-top ventilation |
Gas Configuration | O2, N2O |
Flow Meter | Four tubes [ 0.2 L/min ~ 10 L/min with interlock O2 valve ] |
LCD Display | 7 inch LCD |
Graphic Display | |
Vaporizer | (Maximum 2 mounts) Isoflurane/Enflurane/Sevoflurane/Halothane |
Fresh Gas Compensation | |
I:E Range | |
Pressure Range | |
P trigger Range | |
Monitoring | |
Modes of Ventilation | |
Respiration range | 1 bpm - 99 bpm (1 bpm - 40 bpm under SIMV) |
Concentration Range | 0 % – 5 % (Up to 8 % for Sevoflurane) |
Calibration | Automatic |
Pipeline Input | |
O2 Flush | 25L/min – 75 L/min |
Minute Volume | > 18 L/min |
PEEP | |
Run-time | |
Waveforms | |
Hypoxic Safety System | O2 > 21% |
Alarm | |
Pressure Safety Valve | < 6 kPa |
Volume of CO2 absorber | 0.8 L |
Output Pressure | |
Power Consumption | |
Power Supply | AC 220 V ± 10%, 50 Hz ± 2% |
Battery | |
Current | |
Working Condition | Operational temperature : 5°C ~ 40°C Operational humidity : < 80 % |
Dimensions | 500 x 460 x 320 mm |
Weight | 22 Kgs |
Drive | Electronically controlled, bellow driven |
Tidal Volume | 0 ml – 1500 ml |
Configuration | |
Gas Configuration | O2, N2O |
Flow Meter | 1 l/min – 10 l/min |
LCD Display | 7 inch LCD |
Graphic Display | |
Vaporizer | Single [Isoflurane / Enflurane / Sevoflurane / Halothane] |
Fresh Gas Compensation | 25 l/min – 75 l/min |
I:E Range | 4:1-1:8 |
Pressure Range | |
P trigger Range | |
Monitoring | VT, MV, BPM, Paw |
Modes of Ventilation | IPPV, SIMV, SIPPV, Manual |
Respiration range | 1 bpm – 100 bpm |
Concentration Range | 0% to 5% |
Calibration | Automatic |
Pipeline Input | |
O2 Flush | |
Minute Volume | |
PEEP | |
Run-time | |
Waveforms | Pressure-time, Flow-time, Pressure-volume loop |
Hypoxic Safety System | N2O cut-off valve / O2 > 25% |
Alarm | AC power failure, minute volume too high (low), airway pressure too high ( low ) and insufficiency of O2 and N2O |
Pressure Safety Valve | < 12.5 kPa |
Volume of CO2 absorber | 1.5 L |
Output Pressure | |
Power Consumption | 50 VA |
Power Supply | 100 VAC – 240 VAC, 50 / 60 Hz |
Battery | [Rechargeable Lead-acid battery] 30 minutes ~ 120 minutes |
Current | |
Working Condition | Patient airway pressure range: - 2 kPa ~ 10 kPa Airway monitoring range: 0 ~ 9.9 kPa Pressure limit range: 2.0 kPa ~ 6.0 kPa |
Dimensions | 1190 x 410 x 710 mm |
Weight | 82 Kgs |
Drive | Electronically controlled, pneumatic driven |
Tidal Volume | 20 ml – 1500 ml |
Configuration | |
Gas Configuration | O2, N2O |
Flow Meter | Cascade, 0 L/min -10 L/min |
LCD Display | 7 inch LCD |
Graphic Display | Waveforms of P-T, F-T |
Vaporizer | Isoflurane / Enflurane / Sevoflurane / Halothane |
Fresh Gas Compensation | |
I:E Range | 4:1-1:8 |
Pressure Range | 5 mbar - 80 mbar |
P trigger Range | -20 cmH2O to 20 cmH2O |
Monitoring | |
Modes of Ventilation | |
Respiration range | 1 bpm - 99 bpm (1 bpm - 40 bpm under SIMV) |
Concentration Range | |
Calibration | Automatic |
Pipeline Input | 280 kPa - 600 kPa |
O2 Flush | |
Minute Volume | > 18 L/min |
PEEP | Off 3 - 20 cm H2O |
Run-time | > 30 minutes up to 2 hours |
Waveforms | |
Hypoxic Safety System | N2O cut-off valve / O2 > 25% |
Alarm | |
Pressure Safety Valve | < 12.5 k Pa |
Volume of CO2 absorber | 1.5 L |
Output Pressure | 0.4 ± 0.1 mPa |
Power Consumption | |
Power Supply | AC 220V ± 10%, 50Hz ± 2% |
Battery | Lead-acid battery 12V, 4Ah |
Current | 500 mA (Max) |
Working Condition | |
Dimensions | 700 x 850 x 1400 mm |
Weight | 65 Kgs |
Drive | Electronically controlled, pneumatic driven |
Tidal Volume | 0 ml ~ 1500 ml |
Ventilation Modes | A/C, IPPV, SIPPV, Manual |
Gas Configuration | O2, N2O |
LCD Display | LED display screen |
Vaporizer | Isoflurane / Enflurane |
Medical Gas Pressure Range | 0.32 mPa ~ 0.6 mPa |
Air Pressure Range | 0.32 mPa ~ 0.5 mPa |
Maximum Safety Pressure | ≤ 12.5 kPa |
I:E Range | 1:1.5 ~ 1:1.3 |
O2 Flush | 25 L/min ~ 75 L/min |
O2 Concentration | > 21% |
Respiration Rate | 4 bpm ~ 40 bpm |
Error Tolerance | ≤ ± 4 % |
O2 Flow meter | 0.1 L/min ~ 10 L/min |
N2O Flow meter | 0.1 L/min ~ 10 L/min |
Pressure Safety Valve | <12.5 k Pa |
Airway Pressure Alarm | Lower limit 0.2 kPa ~ 5 kPa Upper limit 0.3 kPa ~ 6 kPa |
Tidal Volume Alarm | Lower limit 0 ml ~ 1800 ml Upper limit 50 ml ~ 2000 ml |
Ventilation Volume Alarm | Lower limit 0 L/ml ~ 12 L/ml Upper limit > 18 L/ml |
CO2 Absorber | Soda lime tank |
Storage: Ambient Temperature | -15°C to 50°C |
Storage: Relative Humidity | < 95% |
Storage: Atmospheric Pressure | 86 kPa ~ 106 kPa |
Power Supply | 100 V ~ 120 V AC, 50/60 Hz |
Dimension | 830 x 770 x 1230 mm |
Weight | 75 Kgs |
Ventilation Modes | IPPV, PCV, SIMV + PS, PS and Manual |
Tidal Volume | 20 ml to 1500 ml |
Pressure (Inspiratory) | 5 cmH2O – 70 cmH2O |
Pressure (Support) | 3 cmH2O – 50 cmH2O |
Electronic PEEP | Off / 3 cmH2O – 30 cmH2O |
I: E Ratio | 4:1 to 1:8 |
Display | 10.4” TFT Colour |
Drive | Pneumatically driven and electronically controlled |
Pressure Trend | Paw, Ppeak, Pplat, Pmean, PEEP |
Volume Monitoring | MV, VT, Freq |
Graph Display | P-T, F-T, P-V, F-V |
Ventilation Gas (Optional CO2, AG, MAC) | FiO2 |
Operational modes | Closed, Semi-closed, Semi-open |
Gas Supply | O2 , Air, N2O |
Ventilator Pressure at Inlet | 280 kPa ~ 600 kPa |
Flowmeter | O2 : 0 ~ 10L/min Air : 0 ~ 12L/min N2O : 0 ~ 10L/min Auxiliary O2 : 0 ~ 12L/min |
Vaporizer | Supports 2 vaporizers |
CO2 Absorption Tank | 3 L Autoclavable |
Vaporizer Filling methods | Pour Fill Key Fill Quick-Fil |
Anaesthetic Agents | Halothane, Enflurane, Isoflurane, Sevoflurane |
APL Range | Spontaneous breathing (SP) -70 cmH2O |
T-slope | 0 ~ 2s |
Plateau (Inspiratory) | Off / 5% – 60% Ti |
Trigger Sensitivity | 1 – 15 L/min |
Alarm | High/Low Airway Pressure, Sustained Airway Pressure, High/Low Minute Volume, High/Low FiO2, High Breath Rate, O2 supply failure, Power failure, Apnea alarm, Mute : 110s |
Power Supply | 100 V ~ 240 V 50/60 Hz |
Battery | 24 V 4Ah ; 120 min |
Dimensions | 760 × 1300 × 630mm |
Weight | 100 Kgs |